| isofloc L |
|
|
| Approval number German Institute for Buiding Technology (DIBt) |
|
Z-23.11-280 |
| Thermal conductivity λ (DIN 4108) |
|
0.040 W / m x K |
| Specific thermal capacity c (J / kg x K) |
|
2150 |
| Water-vapour diffusion resistance factor µ |
|
1-2 |
| Normal moisture content |
|
8-10% at 50% relative humidity
16-18% at 80% relative humidity |
| Fire Resistance |
|
|
| Building materials class/fire classification (DIN 4102-1) |
|
B2 (flammable) smoulders on flame application, non-burning, does not melt or drip. |
| Euro class (EN 13501-1) |
|
E |
| Self-ignition point |
|
ca. 280° C |
| max. continuous temperature |
|
60° C |
| max. short-term peak temperature |
|
90° C |
| Building components (Fire resistance class) |
|
F30-F90 for all building components |
| Acoustic insulation/sound-proofing properties |
|
Test certification of the degree of sound absorption, the longitudinal flow resistance and the dynamic stiffness/rigidity are available.
Test certifications for many building components with various cladding variants and insulation thicknesses are available. |
| Densities according to area applied - as per technical approval |
|
|
| Exposed |
|
30-50 kg / m³ |
| Filling of voids |
|
40-60 kg / m³ |
| Maximum densities for structural calculations |
|
Ceiling/floor: 45 kg / m³
Roof: 55 kg / m³
Wall: 60 kg / m³ |
| Durability |
|
Settle-fast at the prescribed installation densities. Resistant to destruction by rodents and insects. |
| Quality assurance |
|
Third-party control by MPA NRW (Ü) comprehensive self-monitoring, Building site attestation from trained specialist installation companies, sample controls on completed buildings |
| Contents |
|
92% homogenous graded newspaper, 8% Boric Acid and other ingredients |
| Production-related energy consumption |
|
ca. 0.1 kWh / kg |
| Primary energy consumption incl. all processes |
|
ca. 50 kWh / m³ (bei 50kg / m³) |
| Disposal |
|
Re-use or the return to the manufacturer (homogenous material delivery). Thermal utilization, small, homogenous material batches according to the European Waste Catalogue. Waste Code No. 170602
Contaminated material to be disposed of according to the local regulations |